Ch1: Calculation error (indicates steam is saturated)
Ch2: Pressure out-of-range error (allowed range is 0 to 7000 MPa)
Ch3: Temperature out-of-range error (allowed range is 100 to 700
o
C)
Examples:
Temperature 190
o
C
Pressure 2000 kPa
Differential Pres. 20 kPa
K 0.05
Result: Volumetric Steam Flow=0, Steam Density=0, Status=1 (saturated)
Temperature 200
o
C
Pressure 1000 kPa
Differential Pres. 100 kPa
K 0.1
Result: Volumetric Steam Flow=2.20318, Steam Density=4.854, Status=0