Extended AT Commands Manual Page 51 of 70 2009-06-25
Command TE2
Æ
MT2 $$REMOTE_CTRL=<VALUE>
Response TE2
Å
MT2
$$REMOTE_CTRL: <VALUE><.> (USE UPPER CASE –
must be followed by a ‘full stop’ as noted)
<result_code> (OK or ERROR)
10.1.2.2. Read ALL request
This command incorporates the VBATT, RSSI, LOCATION & SWVER SMS automated response
request in one command.
Table 10-67 Read Command
Command from SMS phone
Enter directory number of specific MT2
Enter message “<remote_ctrl_value>.all” (not case
sensitive)
Send message
Response from MT2
<directory_number><report><time_date_stamp><remote_ctrl
_value>
Value
directory_number: phone number of remote MT2
report: lists reports of VBATT, RSSI, LOCATION & SWVER
time_date_stamp: hour day month,
remote_ctrl_value: default or user defined name
‘Site name’ is only incorporated within the ‘remote_ctrl_value.all’ request response and not the
individual request responses that follow.
10.1.2.3. VBATT request
Read supply voltage at remote MT2.
Table 10-68 Read command
Command from SMS phone
Enter directory number of specific MT2
Enter message “maxon.vbatt” (not case sensitive)
Send message
Response from MT2 <directory_number> VBATT: <time_date_stamp>
Value
directory_number: phone number of remote MT2
time_date_stamp: hour day month
10.1.2.4. RSSI request
Read RSSI at remote MT2.
Table 10-69 Read command
Command from SMS phone
Enter directory number of specific MT2
Enter message “maxon.rssi” (not case sensitive)
Send message
Przeglądanie stron 50